The HANA MODZ Pack V3 is a DNA 40 temperature protected device. The body is made of 6061 Billet Aluminum. Built in DNA charger; which is MICRO USB powered and provides a 500 milliamp charge current. The DNA 40 is a power regulated digital switch-mode DC-DC converter for personal vaporizers.

It features Evolv’s patented:

  • Wattage Control
  • Temperature Protection
  • Preheat
  • Step Up/Step Down Topology
  • Digital User Controls
  • OLED Screen
  • Onboard Buttons
  • Synchronous Rectification for maximum battery life and minimal heat generation.

It is the most advanced personal vaporizer controller ever made.

Hana Modz DNA 40 Operation Guide

Basic operation of the DNA 40 is as follows. To wake the device from power off state, tap the Fire button. To generate vapor, press the Fire button. To change the
wattage setting for more or less vapor, click or hold the Up and Down buttons.

Attaching a New Atomizer: The DNA 40 uses the resistance of the atomizer to calculate the temperature of the heating coil. It continually looks to see whether a new or changed atomizer has been connected. If you are using temperature protection, be careful to only attach new atomizers that have cooled to room temperature to the device. If a new atomizer is attached to the DNA 40 before it has cooled down, the temperature may read and protect incorrectly until the new atomizer cools. When you connect a new atomizer or disconnect and reconnect your existing atomizer, the DNA 40 will prompt you to confirm this change. When you fire the first time, before activating the DNA 40 will prompt “New Coil? UP YES/DOWN NO”. When you see this prompt, if you have attached a new atomizer, press the UP button. If you have disconnected and reconnected the same atomizer, press the DOWN button.

Temperature Protected

  • Watt setting: The power level currently set on the DNA 40. Battery indicator: The current state of charge of the battery.
  • Temperature display: When not firing, the maximum heating coil temperature setting. While firing, the actual temperature of the heating coil is displayed.
  • Ohms display: The resistance of the atomizer attached to the device. This is measured only when the unit is supplying power to the atomizer. At other times, it shows the most recent measurement.
  • Temperature Protection The DNA 40 is the first power supply for electronic cigarettes to directly measure and limit the temperature of the heating coil during operations. By preventing the coil from becoming too hot regardless of fluid, wicking or airflow, a variety of undesirable situations can be prevented. For example, appropriate temperature settings will prevent the wicking material from charring, which compromises taste and introduces unintended chemicals into the vapor. Appropriate temperature setting will also reduce the breakdown of flavoring and base liquid components, which could impact taste or safety. Evolv's Temperature Protection Technology requires a heating coil made from Nickel 200 alloy, rather than Nickel Chromium or Kanthal alloys. Nickel 200 is commercially pure nickel. It is often sold in vapor shops and online as "non-resistance wire". If the temperature reaches the maximum value, the wattage applied to the atomizer coil is reduced to prevent overheating. Please note that the temperature reading is the average temperature of the atomizer coil so that the temperature is uniform, without hot or cold spots. Ensure that the coil does not short to itself. Because wattage, not temperature controls vapor volume, large vapor volumes can be produced without unnecessarily high temperatures. Temperature Protection is most helpful if the atomizer begins to dry out, the user pauses during a puff, the beginning or end of the puff, or if the wattage setting is inappropriate for the attached atomizer. In normal operation, when the device is not firing the maximum temperature setting is displayed on the screen. When the device is firing, the actual average temperature of the coil is displayed on the screen. By default, the Temperature Protection setting is 450 Fahrenheit. 
  • Preheat When the DNA 40 is used with a temperature sensing atomizer, an additional feature called Preheat is activated. No vapor is produced when the temperature when the temperature is below the boiling point of the liquid. Preheat applies extra power until the heating coil is up to operating temperature to shorten the delay between pressing the fire button and generating vapor. Because the preheat is temperature based, it will not overheat or burn the vapor. Attaching a New Atomizer The DNA 40 used the resistance of the atomizer to calculate the temperature of the heating coil. It continually looks to see whether a new or changed atomizer has been connected. If you are using temperature protection, be careful to only attach new atomizers that have cooled to room temperature to the device. If a new atomizer is attached to the DNA 40 before it has cooled down, the temperature may read and protect incorrectly until the new atomizer cools. When you connect a new atomizer or disconnect and reconnect your existing atomizer, the DNA 40 will prompt you to confirm this change. When you fire the first time, before activating the DNA 40 will prompt "New Coil? UP YES/DOWN NO". When you see this prompt, if you have attached a new atomizer, press the UP button. If you have disconnected and reconnected the same atomizer, press the DOWN button.

Non-temperature Protected

  • Watt setting: The power level currently set on the DNA 40. Battery indicator: The current state of charge of the battery. Volts display: The output voltage being supplied to the atomizer.
  • Ohms display: The resistance of the atomizer attached to the device. This is measured only when the unit is supplying power to the atomizer. At other times, it shows the most recent measurement.

Modes

  • Locked mode: Pressing the fire button five times with less than .7 seconds between presses will cause the device to enter Locked mode. In Locked mode, the device will not fire and the output power will not adjust accidentally. While in Locked mode, the screen will be off, except that pressing a button will show “Locked, Click 5X”. To exit Locked mode, press the fire button 5 times.
  • Stealth mode: While locked, holding the fire and down buttons simultaneously for five seconds will switch to stealth mode. In this mode the display is off. It will still show error and lock messages. To switch back to normal display mode, hold down the fire and down buttons simultaneously for 5 seconds. This setting is stored to internal flash memory, and remains if power is removed.
  • Right mode and left mode: While locked, holding the fire and up buttons simultaneously for 5 seconds flips the display. This allows for maximum flexibility in designing the mod, as well as accommodating left handed use. This setting is stored to internal flash memory, and remains if power is removed.
  • Power locked mode: Holding down both the up and down buttons for two seconds will place the device in Power Locked mode. In this mode, the mod will operate normally, but you will not be able to change the power setting. This mode prevents accidental power level changes due to the buttons being pressed while in a pocket. To exit Power Locked mode, hold the up and down buttons for two seconds.
  • Auto Power Down: The screen will be at full brightness while firing. After 10 seconds with no button presses, the screen will dim. 30 seconds after the last button press, the screen will fade out and the device will go into sleep mode. To wake the device, press the fire button.
  • Max temperature adjust: From Locked Mode, holding down both the up and down buttons for two seconds will place the device in Max Temperature Adjust mode. Once this mode is entered, the max temperature will be displayed. The up and down buttons are used to adjust the max temperature. To save the new temperature setting and exit, press the Fire button.

Error Messages
The DNA 40 will indicate a variety of error states.

  • Check atomizer: The DNA does not detect an atomizer, the atomizer has shorted out, or the atomizer resistance is incorrect for the power setting.
  • Shorted: The atomizer or wiring are short circuited.
  • Weak battery: The battery needs to be charged, or a higher rate battery needs to be used. If this happens, the DNA 40 will continue to fire the atomizer, but will not be able to provide the desired wattage. The Weak Battery message will continue to flash for a few seconds after the end of puff.
  • Temperature protection: The heating coil reached the maximum allowed temperature during the puff. If this happens, the DNA 40 will continue to fire, but will not be able to provide the desired wattage.
  • Ohms too high: The resistance of the atomizer coil is too high for the current wattage setting. If this happens, the DNA 40 will continue to fire, but will not be able to provide the desired wattage. The Ohms Too High message will continue to flash for a few seconds after the end of puff.
  • Ohms too low: The resistance of the atomizer coil is too low for the current wattage setting. If this happens, the DNA 40 will continue to fire, but will not be able to provide the desired wattage. The Ohms Too Low message will continue to flash for a few seconds after the end of puff.
  • Too hot: The DNA 40 has onboard temperature sensing. It will shut down and display this message if the internal board temperature becomes excessive.

For full specification please visit our website at www.hanamodz.com

Warranty

Due to the nature of the product, all sales are final. Please contact the manufacturer directly for any issues and their warranty policies.